Cecile created a test message using Madelynn Snow test script and generated it in BYIM test for Nathan's review. 

I have checked it against the NIST validater and here are the issues I'm seeing:
•	The code table for PID-10 should be CDCREC instead of HL70005
•	If the value for PID-22 is unknown then nothing should be placed in this field. 
•	If no Next-of-Kin is defined then the entire segment should not be sent. Currently the segment has no name it but it is still being sent. 
•	The code value for RXA-2 Body Site is incorrect. 

The last bullet was likely a data entry error.  Are these other items something to look at in BYIM?