Issue 1: Quality report's metrics are wrong on the plate page
1 person starred this issue and may be notified of changes. Back to list
Status:  Fixed
Owner:  aborgabor
Closed:  Feb 2009


 
Project Member Reported by aborgabor, Nov 25, 2008
Quality report's metrics are wrong on the plate page if more than one
channel/parameter is measured. (Only the first column is correct.)

What steps will reproduce the problem?
1. Try to analyze an experiment with more than one parameters.

What is the expected output? What do you see instead?
Floating point outputs same as on the main screen.

Jan 29, 2009
Project Member #1 aborgabor
Maybe related to this line:
   if (exists("qmplate")) qmplate <- cbind(qmplate, value=qm$value, comment=qm$comm)
else qmplate = qm

But I cannot reproduce with R 2.8.1 and cellHTS2 2.6.0.
Feb 2, 2009
Project Member #2 aborgabor
(No comment was entered for this change.)
Status: Started
Feb 2, 2009
Project Member #3 aborgabor
The output now seems to be OK. Though the workaround is not so beauty...
Status: Fixed