| Issue 179: | Special handler for MC35i respondig with CME ERROR:100 on ATZ. | |
| 1 person starred this issue and may be notified of changes. | Back to list |
Sign in to add a comment
|
Hi. I got my hand on two suspicious Siemens MC35i modems. These two are unique by responding with CME ERROR:100 on every ATZ (and not responding on 'AT+CPIN?' that follows). This leads to infinite modem restarting. Issuing AT&F and storing defaults by AT&W didn't help. By some mysterious reasons replacing ATZ with AT&F in 'sync' and 'reset' methods of ATHandler made it to work (looks like stable enough). I made special MC35i handler (extending default MC35i) which uses AT&F to restore default settings. This handler can be used in cases where this model fails to init properly (and sacrificing ability to use custom user config from ATZ). Maybe it was just a defective shipment, however having this handler won't hurt I think. This issue will stay as remainder until patch is submitted. Thanks. |
||||||||||||
,
Feb 04, 2009
Hi, Thanks for this. I would certainly not hurt. We would just need an alternate name for this new handler - a firmware revision marker maybe(?)
Summary: Special handler for MC35i respondig with CME ERROR:100 on ATZ.
Status: Accepted Labels: Component-SMSLib Priority-Medium |
|||||||||||||
,
Feb 05, 2009
Firmware is the same for both normal and malfunctioning modems. They are absolutely equal if not taking S/N into account. Name for the new ATHandler is Siemens_MC35i_FD. FD stands for 'Factory Defaults'. |
|||||||||||||
,
Feb 05, 2009
r1737
Status: Completed
Labels: Milestone-v3.4.0 |
|||||||||||||
,
Mar 29, 2009
(No comment was entered for this change.)
Status: Fixed
|
|||||||||||||
|
|
|||||||||||||